Heating - Boilers - Furnace Systems and Facility Mechanical Services.
. .

Residential and Commercial Property Boiler - Services for Controls, Stack, Radiators and Thermostat.
 

 

Air Conditioning and Heating Services Price List.

Heating, Energy, Information and Costs.

Heat Pumps - Philadelphia.

HVAC Systems and Equipment, Philadelphia.

HVAC Services for Commercial Properties, Philadelphia.

Plumbing, Radiators, Circulators Pumps, Philadelphia.

Ventilation Systems and Benefits.

Water Heater Cost Information.

Water Pumping Systems.

Urgent Contractor Services - Philadelphia.

HVAC Contractors.

Oil / Fuel Burner Service Philadelphia.


ask us about your boiler - Efficiency, Fuel, Stack, Cleaning and Improvement Services.
 Hi Tech Boilers, Upgrades for Boiler Accessories ... Ask us about it.
Need an estimate on a change over?
Information is our business and we're ready to work for you.
Learn more about high efficiency boilers for space and hot water heating applications in your property. Gas and oil boilers for both water and steam heating applications along with energy-efficient indirect hot water heaters are always available. ENERGY STAR products and control systems offer the best heating solutions available. Contact us for heating contractors and dealers of the best boiler products and support from the Hydronic industry.

Count on us for quick and reliable services for all your heating and HVAC needs.

Electronic ignition boilers burns fuel only as necessary, reducing energy costs Thick fiberglass insulation—minimizes off-cycle heat loss. Induced draft fan—optimizes venting of combustion gases for greater heat transfer and efficiency.

Tubeless Vertical - Hot Water Boilers provide for exceptionally high efficiencies, lower fuel costs, and extremely rugged construction. Compact space saving vertical design four-pass design shock proof, no tubes to loosen or burn out. Convenient access to "eye high" burner solid state controls for trouble free operation factory assembled, fully automatic UL and ASME CSD-1. Simple and inexpensive to install.
Firebox - Efficient 3-pass design, fuel flexibility for gas, oil, heavy oil, and combination gas/oil, ASME code constructed & stamped for 15 psi steam/30 water registered with the National Board of Boiler Inspectors, competitively priced, easily maintained, designed for efficiency, large furnace volume for ultimate combustion efficiency unified refractory base floor, steel skids and lifting eyes, low heat release.  Second we must install the power supply wiring to points of connection. This can be done during the ordering time to be ready for the installation. The operation of the heaters is normally manual, but if an automatic system is required we can design it for you.

We Welcome  your questions.
We can estimate your job by email.
Boiler fittings and accessories Safety valve: It is used to relieve pressure and prevent possible explosion of a boiler. Water level indicators: They show the operator the level of fluid in the boiler, also known as a sight glass, water gauge or water column is provided. Bottom blowdown valves: They provide a means for removing solid particulates that condense and lie on the bottom of a boiler. As the name implies, this valve is usually located directly on the bottom of the boiler, and is occasionally opened to use the pressure in the boiler to push these particulates out. Continuous blowdown valve: This allows a small quantity of water to escape continuously. Its purpose is to prevent the water in the boiler becoming saturated with dissolved salts. Saturation would lead to foaming and cause water droplets to be carried over with the steam - a condition known as priming. Blowdown is also often used to monitor the chemistry of the boiler water. Flash Tank: High pressure blowdown enters this vessel where the steam can 'flash' safely and be used in a low-pressure system or be vented to atmosphere while the ambient pressure blowdown flows to drain.
Automatic Blowdown/Continuous Heat Recovery System: This system allows the boiler to blowdown only when makeup water is flowing to the boiler, thereby transferring the maximum amount of heat possible from the blowdown to the makeup water. No flash tank is generally needed as the blowdown discharged is close to the temperature of the makeup water. Hand holes: They are steel plates installed in openings in "header" to allow for inspections & installation of tubes and inspection of internal surfaces. Steam drum internals, A series of screen, scrubber & cans (cyclone separators). Low- water cutoff: It is a mechanical means (usually a float switch) that is used to turn off the burner or shut off fuel to the boiler to prevent it from running once the water goes below a certain point. If a boiler is "dry-fired" (burned without water in it) it can cause rupture or catastrophic failure. Surface blowdown line: It provides a means for removing foam or other lightweight non-condensable substances that tend to float on top of the water inside the boiler. Circulating pump: It is designed to circulate water back to the boiler after it has expelled some of its heat. Feed water check valve or clack valve: A non-return stop valve in the feed water line. This may be fitted to the side of the boiler, just below the water level, or to the top of the boiler. Top feed: A check valve (clack valve) in the feed water line, mounted on top of the boiler. It is intended to reduce the nuisance of lime scale. It does not prevent lime scale formation but causes the lime scale to be precipitated in a powdery form which is easily washed
out of the boiler.
Radiant Heating Installations. Job Costs and Trade Assistance for Economical Radiant Heating Installations all around The Delaware Valley, by Contractors Solutions Inc. - Philadelphia.
Germantown Philadelphia, Action Information Sponsored by the Hard-Working Property Trades near you.